Part Number Hot Search : 
HN9C01FT 13003H1 UAA2016D 2SJ548 BRB304 5233B 80N06 P1300
Product Description
Full Text Search
 

To Download 48132-01 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 


WE'RE BIG ON BRUSHLESS

TM

B R U S H L E S S D C M OTO R S * B L OW E R S * C O N T R O L L E R S
ROTRON Technical Products




Table of Contents
Introduction ............................................... 1, 2, 3 BLDC Motors
1.7" (43mm) diameter ........................................... 4, 5 2.5" (64mm) diameter ........................................... 6, 7 3.0" (79mm) diameter ........................................... 8, 9 3.55" (90mm) diameter ....................................... 10, 11 3.9" (99mm) diameter ....................................... 12, 13 5.25" (133mm) diameter ..................................... 14, 15
Low Voltage Blowers (BLDC)
2.9" (74mm) ...................................................... 16, 17 3.0" (76mm) ....................................................... 18, 19 3.3" (84mm) ....................................................... 20, 21 4.5" (114mm) ..................................................... 22, 23 5.0" (127mm) MINIJAMMER (R) ............................. 24, 25 5.1" (130mm) ..................................................... 26, 27 5.7" (145mm) WINDJAMMER (R) ........................... 28, 29
High Voltage Blowers (BLDC)
WINDJAMMER (R) 5.7" (145mm) Thru Flow/250 Watt/120VAC ..... 30, 31 5.7" (145mm) Bypass/250 Watt/120VAC .......... 32, 33 5.7" (145mm) Thru Flow//400 Watt/240 VAC ... 34, 35 5.7" (145mm) Bypass/400 Watt/240VAC .......... 36, 37 5.7" (145mm) Bypass/800 Watt/120VAC .......... 38, 39 5.7" (145mm) Bypass/1200 Watt/240VAC ........ 40, 41
Controllers (BLDC)
5 10 20 Amp Motor/Blower .......................................... 42 Amp Motor/Blower .......................................... 43 Amp Motor ...................................................... 44
BLDC Motor/Blower Controller Part Numbers ................................ 45 Blower/Motor Sizing Sheet ............................ 46 Application Engineering Basics ................................................. 47, 48, 49, 50, 51 AMETEK Global Locations ........................ 52, 53 Contact Information ....................................... 54
The AMETEK Electromechanical Group (EMG). . .
is one of the world's largest producers of high-speed electric motor products for original equipment manufacturers (OEMs). In business since 1915, EMG uses its core competencies in motion and air movement products as engineered solutions for application-specific needs. A unit of AMETEK EMG, Rotron offers Brushless DC motor-, blower-, and controller-based solutions.
The standard product lines of Rotron Technical Products cover a wide range of application demands. If there is a need for a product with unique performance, mounting, environment or agency requirements, Rotron can supply the solution. Whether a customer needs a standard or special design, Rotron has the solution for your application. AMETEK offers economies of scale that only can be accomplished by a company that produces more than 23 million motor products per year. With multiplant capability and flexibility, Rotron is positioned to support our customers' global programs. AMETEK Brushless DC Motors and Blowers are an ideal choice for such varied applications as medical instruments, robotics, pumps, compressors, business equipment, fans, machine tools, tape drives, or any other precise rotary motion/air delivery applications.
1
INTRO99
Brushless DC Motors. . .
offer precise control for a wide range of applications. Rotron standard motor designs offer maximum controllable performance, coupled with the reliability of brushless technology in a compact cost effective package. First introduced in 1988, the AMETEK brushless DC motor product line has continually expanded into one of the largest mixes of fractional horsepower motor products in the industry.
Motor Selection. . .
is made easy with the wide variety of standard products available from AMETEK. Six different motor families are available in standard configurations. These include 1.7" (43mm), 2.5" (64mm), 3.0" (76mm), 3.55" (90mm), 3.9" (99mm), and 5.25" (133mm) diameter motors, with constant torque which range from 5.75 oz. in. (4.06 Ncm) to 832 oz. in. (5.87 Nm) and horsepower ratings of .014 to 1.75. Voltage options range from 12VDC to 74VDC. The table below provides a summary of the motor products, operating voltages, speed and torque ranges sorted by motor diameter. Use this chart to compare the AMETEK products to the application needs. Detailed motor information is provided on the individual product sheets.
BLDC MOTORS Motor Diameter 1.7" (43mm) 2.5" (64mm) 3.0" (76mm) 3.55" (90mm) 3.9" (99mm) 5.25" (133mm) Operating Voltage (DC) Controller Input 12, 24, 36 12, 24, 36 13.8, 24, 27.6 12, 24, 36 12. 13.8, 27.6, 74 27, 27.6, 74 Speed Range (RPM) at Nom. Continuous Torque 0 - 3,000 0 - 5,000 0 - 4,930 0 - 4,300 0 - 4,500 0 - 4,055 Torque Range (oz. in.) Maximum Continuous 5.75 - 11 14 - 69 19.7 - 55 22 - 132 28 - 100 192 - 832
Motor Controllers
All of the AMETEK BLDC Motors require a controller to operate. The controllers require a DC input which is processed into phase drive signals. The 1.7" (43mm) and 3.0" (76mm) motors are available with integrated controllers. All other motors require an external controller. Controller details and compatibility to the different motor products are supplied in the controller section of the catalog.
2
INTRO99
Brushless DC Blowers. . .
offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower designs offer brushless DC motor drives coupled to high efficiency fan systems in a compact, cost effective package. Standard models are available in a wide range of input voltages, including 12, 24, 28, and 36VDC. A complete product line of brushless DC blowers that accepts line voltage input (120VAC and 240VAC) also is available. AMETEK brushless DC blowers are not designed for, and should not be used in, life sustaining applications. AMETEK brushless DC blowers are not 100% sealed and therefore should not be used with flammable or hazardous gases.
Blower Selection. . .
offers a wide variety of standard products available from AMETEK. Thirteen different blower families are available in standard configurations. These include seven low voltage and six high voltage products. The low voltage products provide outputs which range from 0 to 28" H20 (pressure) at flows of 0 to 45 CFM. The high voltage products provide outputs which range from 0 to 162" H20 (pressure) at flows of 0 to 275 CFM.
LOW VOLTAGE PRODUCTS Blower Diameter 2.9" (74mm) 3" (76mm) 3.3" (84mm) 4.5" (114mm) 5" (127mm) 5.1" (130mm) 5.7" (145mm) Operating Voltage (DC) 12, 24 12, 24 12, 24 12, 24 12, 24 12, 24 12, 24, 36 CFM Range 0-22 0-18 0-7 0-9 0-45 0-15 0-39 In. H20 (Pressure) 0-3 0-10 0-27 0-28 0-24 0-25 0-28 In. H20 (Vacuum) 0-28
HIGH VOLTAGE BYPASS PRODUCTS Blower Diameter 5.7" (145mm) 5.7" (145mm) 5.7" (145mm) 5.7" (145mm) Operating Voltage (AC) 120 (250 Watt) 120 (800 Watt) 240 (400 Watt) 240 (1200 Watt) CFM Range 0-115 0-242 0-115 0-275 In. H20 (Pressure) 0-76 0-115 0-144 0-162 In. H20 (Vacuum) 0-65 0-106 0-135 0-118
HIGH VOLTAGE THRU-FLOW PRODUCTS Blower Diameter 5.7" (145mm) 5.7" (145mm) Operating Voltage (AC) 120 (250 Watt) 240 (400 Watt) CFM Range 0-117 0-67 In. H20 (Pressure) 0-75 0-50 In. H20 (Vacuum) 0-70 0-47
3
INTRO99
1.7" (43mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
Motor Data
No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above)
Unit of Measure
RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches mm
Part Numbers
119272* 4388 .16 12.7 8.96 5.75 4.06 2425 1.0 10 7.39 5.21 5.47 0.052 .273 .202 2.37 1.67 8.00 x 10-6 0.0565 9.74 2.66 3.5 1.864 47.35 .51 0.23 .75 19.05 119275* 4308 .18 51.3 36.20 11 7.77 3000 1.75 24 7.53 5.31 5.57 0.053 .339 .134 4.12 2.91 1.60 x 10-5 0.0113 3.34 1.13 1.90 2.614 66.40 .78 0.35 1.00 25.40
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
4
1.7M99
1.7" (43mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
5
1.7M99
2.5" (64mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
Motor Data
No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above)
Unit of Measure
RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches mm
Part Numbers
119000* 5947 1.14 142 100 14 10 4928 3.7 51 5.46 3.85 4.04 0.0385 0.838 5.236 6.8 4.8 0.0017 0.0012 0.648 0.543 1.26 2.335 59.31 1.15 0.52 .750 19.05 119001 5389 1.07 179 127 21 15 4234 4.6 66 6.02 4.25 4.45 0.0425 0.886 4.129 8.1 5.7 0.0019 0.0013 0.557 0.493 1.22 2.335 59.31 1.25 0.57 .750 19.05 119002 4233 0.93 191 135 27 19 3286 4.5 66 7.67 5.42 5.67 0.0542 0.937 4.080 9.3 6.6 0.0025 0.0018 0.678 0.635 1.19 2.835 72.01 1.60 0.73 .750 19.05 119003* 5468 1.08 267 189 34 24 4228 6.8 106 5.94 4.19 4.39 0.0419 0.904 3.775 10.1 7.1 0.0027 0.0019 0.348 0.314 1.15 2.835 72.01 1.75 0.79 .750 19.05 119004 4636 0.98 282 199 41 29 3455 6.8 105 7.00 4.94 5.18 0.0494 0.938 4.006 11.1 7.9 0.0035 0.0025 0.396 0.372 1.11 3.585 91.06 2.15 0.98 1.500 38.1 119005 4019 0.91 294 208 48 34 3074 6.8 109 8.08 5.70 5.97 0.0570 0.965 3.668 12.1 8.6 0.0038 0.0027 0.444 0.429 1.08 3.585 91.06 2.25 1.02 1.500 38.1 119006 3575 0.85 302 213 55 39 2645 6.9 108 9.08 6.41 6.71 0.0641 0.986 3.217 12.9 9.1 0.0038 0.0027 0.493 0.486 1.04 3.585 91.06 2.30 1.04 1.500 38.1 119007 3191 0.81 311 219 62 44 2290 6.9 105 10.17 7.18 7.52 0.0718 1.004 3.258 13.8 9.8 0.0044 0.0031 0.541 0.543 1.00 4.085 103.76 2.70 1.22 1.875 47.63 119008* 2879 0.77 319 225 69 49 2002 6.9 102 11.27 7.96 8.34 0.0796 1.019 3.021 14.7 10.4 0.0046 0.0032 0.589 0.601 0.96 4.085 103.76 2.80 1.27 1.875 47.63
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section ( page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
6
2.5M99
2.5" (64mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
7
2.5M99
3.0" (79mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Motor Data
Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Drive Electronics Electronic Drive Part Number *Part Number 150007 has a dual shaft.
Unit of Measure
Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm Internal or External
Part Numbers
150004 13.8 3770 0.75 169 119 19.7 13.9 2927 4.6 43 4.90 3.46 3.66 0.035 3.25 82.63 1.7 0.776 .3152 8.0060 1.87 47.50 Internal *150007 27.6 5510 1 1300 915 43 30 4930 6.9 157 7.43 5.25 5 0.048 3.77 95.76 3 1.359 .281 7.137 3.50/3.50 88.90/88.90 External 48129-03 E-11488 24.0 5400 1.5 1298 917 55 39 4400 9.9 181 6.00 4.24 4.44 0.0424 4.27 108.46 TBD .281 7.137 1.37 34.75 External 48129-11
NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
8
3.0M99
3.0" (79mm) Diameter, 4 Pole, Brushless DC Motor
External Drive Part Number 48129-03
External Drive Part Number 48129-11
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
9
3.0M99
3.55" (90mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
Motor Data
No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above)
Unit of Measure
RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches mm
Part Numbers
119050* 4319 1.48 284 201 22 16 3715 4.4 60 7.52 5.31 5.56 0.0531 1.055 14.713 11.5 8.1 0.0138 0.0097 0.425 0.449 1.21 2.500 63.50 2.10 0.95 .750 19.05 119051 5259 1.74 375 265 36 25 4342 7.6 116 6.17 4.36 4.56 0.0436 1.052 13.065 12.5 8.9 0.0145 0.0102 0.242 0.255 1.19 2.500 63.50 2.25 1.02 .750 19.05 119052 4067 1.41 428 302 49 35 3265 7.6 118 7.98 5.64 5.90 0.0564 1.140 12.005 15.0 10.6 0.0191 0.0135 0.283 0.322 1.17 3.000 76.20 2.80 1.27 .750 19.05 119053* 3434 1.24 453 320 63 44 2641 7.9 123 9.45 6.68 6.99 0.0667 1.205 10.293 16.6 11.7 0.0201 0.0142 0.323 0.389 1.15 3.000 76.20 3.00 1.36 .750 19.05 119054 2838 1.07 496 350 77 54 2174 7.8 124 11.44 8.08 8.46 0.0808 1.256 11.253 19.0 13.4 0.0286 0.0202 0.363 0.457 1.13 3.750 95.25 3.75 1.70 1.500 38.10 119055 2543 0.99 505 357 91 64 1864 8.1 126 12.77 9.02 9.44 0.0901 1.297 10.283 20.1 14.2 0.0293 0.0207 0.404 0.524 1.11 3.750 95.25 4.00 1.81 1.500 38.10 119056 2281 0.92 518 366 105 74 1605 8.3 125 14.23 10.05 10.52 0.1005 1.331 9.413 21.4 15.1 0.0303 0.0214 0.444 0.591 1.09 3.750 95.25 4.20 1.90 1.500 38.10 119057 2021 0.85 541 382 119 84 1377 8.3 121 16.06 11.34 11.88 0.1134 1.358 9.313 23.1 16.3 0.0350 0.0247 0.485 0.658 1.06 4.250 107.95 4.70 2.13 1.875 47.63 119058* 1856 0.80 549 387 132 93 1214 8.4 119 17.49 12.35 12.93 0.1235 1.382 8.754 24.1 17.0 0.0360 0.0254 0.525 0.726 1.04 4.250 107.95 4.85 2.20 1.875 47.63
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
10
3.55M99
3.55" (90mm) Diameter, 8 Pole, Brushless DC Motor
24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK RTMD products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
11
3.55M99
3.9" (99mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Motor Data
Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Drive Electronics
Unit of Measure
Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm
Part Numbers
071033 12 6700 1 72 51 28 20 4500 14 94 2.42 1.71 1.79 0.0171 5.33 135.38 6.4 2.9 .2495 6.337 .83 21.08 Internal 071070 13.8 3750 2.5 210 148 60 42 2527 14.3 113 4.98 3.51 3.68 0.0351 6.08 154.43 7.3 3.3 .6250 15.8750 1.00 25.40 Internal 071031 74 3700 0.22 334 236 85 60 2700 3.2 171 27.04 19.10 20 0.1910 6.68 169.67 8.0 3.6 .312 7.925 1.65 41.91 Internal 071145 27.6 3000 0.5 453 320 100 71 2100 8 155 12.44 8.79 9.20 0.0879 7.68 195.07 9.3 4.2 .4997 12.6924 2.25 57.15 Internal
NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
12
3.9M99
3.9" (99mm) Diameter, 4 Pole, Brushless DC Motor
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
13
3.9M99
5.25" (133mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
Motor Data
Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Drive Electronics Drive Electronics Part Number *Part Number 524506 has a dual shaft.
Unit of Measure
Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm Internal or External
Part Numbers
528512 27.6 4055 1.6 2403 1697 192 136 3250 23 467 9.20 6.21 6.81 0.0621 6.76 171.70 18 8.2 .3747 9.5174 1.00 25.40 Internal N/A 071087 27 1935 0.8 4380 3094 368 260 1573 20 433 18.85 13.31 13.94 0.1331 7.86 199.64 20 9.1 .6250 15.8750 2.06 52.32 Internal N/A 071190 27 1765 0.7 6400 4519 560 395 1445 27.5 605 20.68 14.61 15.30 0.1461 10.36 263.14 23 10.4 .7497 19.0424 3.25 82.55 Internal N/A 524647 74 2565 0.62 18000 12707 720 508 2253 18.5 1214 39.01 27.55 28.85 0.2755 8.91 226.31 24 10.9 .7497 19.0424 7.09 180.09 External 524731 *524506 27 2000 2.5 15383 10862 832 587 1750 46.0 1090 18.25 12.89 13.50 0.1289 10.09 256.29 27 12.2 .6250 15.8750 2.05/2.05 52.07/52.07 External 524508
NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
14
5.25M99
5.25" (133mm) Diameter, 4 Pole, Brushless DC Motor
External Drive Part Number 524731 524508
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
15
5.25M99
2.9" (74mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow)
Unit of Measure
VDC in. H2O, Sealed mBar CFM L/sec
Part Number
119495 12 1 3.4 8.4 22 10.4 119496 24 1 3.4 8.4 22 10.4
Air Flow
0 CFM 4 CFM 8 CFM 12 CFM 16 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O 3.4 3.1 2.9 2.5 1.8 3.4 3.1 2.9 2.5 1.8
Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
16
2.9BLV99
2.9" (74mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
17
2.9BLV99
3.0" (76mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow)
Unit of Measure
VDC in. H2O, Sealed mBar CFM L/sec
Part Number
119349* 12 1 10 24.9 18 8.5 119350* 24 1 10 24.9 18 8.5
Air Flow
0 CFM 4 CFM 8 CFM 12 CFM 16 CFM 18 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 10 9.1 7.6 5.4 2.4 0 10 9.1 7.6 5.4 2.4 0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
18
3BLV99
3.0" (76mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
19
3BLV99
3.3" (84mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow)
Unit of Measure
VDC in. H2O, Sealed mBar CFM L/sec
Part Number
119497 12 1 27.3 67.9 7.5 3.5 119498 24 1 27.3 67.9 7.5 3.5
Air Flow
0 CFM 2 CFM 4 CFM 6 CFM 8 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O 27.0 26.0 20.5 9.0 0 27.0 26.0 20.5 9.0 0
Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
20
3.3BLV99
3.3" (84mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
21
3.3BLV99
4.5" (114mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow)
Unit of Measure
VDC in. H2O, Sealed mBar CFM L/sec
Part Number
119494 12 1 28.4 70.7 9.1 4.3 119395 24 1 28.4 70.7 9.1 4.3
Air Flow
0 CFM 2 CFM 4 CFM 6 CFM 8 CFM 10 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 28.4 26.2 22.4 15.3 5.6 0 28.4 26.2 22.4 15.3 5.6 0
Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
22
4.5BLV99
4.5" (114mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
23
4.5BLV99
5.0" (127mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Drive Electronics
Unit Measure
119380 VDC in. H2O mBar CFM L/sec Internal or External 12 1 12 30 34 16 External
Part Number Standard Flow
119381 M 119382 E 12 1 12 30 34 16 Internal 119383 24 1 12 30 34 16 External 119384 M 119385 E 24 1 12 30 34 16 Internal
High Output
119375 24 1 24 60 45 21 External 119378 M 119379 E 24 1 24 60 45 21 Internal
Air Flow
0 CFM 10 CFM 20 CFM 30 CFM 40 CFM in. H2O in. H2O in. H2O in. H2O in. H2O
Typical Performance Points Pressure
12.5 11.7 7.6 2.3 12.5 11.7 7.6 2.3 12.5 11.7 7.6 2.3 12.5 11.7 7.6 2.3 24.3 22.0 18.4 10.8 3.5 24.3 22.0 18.4 10.8 3.5
NOTES: Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max. Speed Control: Internal - E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and speed control. AMETEK blower controller part numbers 48069 for 12VDC blowers and 48070 for 24 VDC blowers are design for use with the above blowers.
24
5BLV99
5.0" (127mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
25
5BLV99
5.1" (130mm) BLDC Low-Voltage Blower
12/24 VDC
Blower Data
Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow)
Unit of Measure
VDC in. H2O, Sealed mBar CFM L/sec
Part Number
119396 12 1 25.70 64 15.30 7.22 119397 24 1 25.70 64 15.30 7.22
Air Flow
0 CFM 2 CFM 4 CFM 6 CFM 8 CFM 10 CFM 12 CFM 14 CFM 16 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 25.7 23.8 21.7 19.5 16.5 12.0 7.1 2.2 0 25.7 23.8 21.7 19.5 16.5 12.0 7.1 2.2 0
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection. Input voltages listed in the chart above indicate the controller input voltage requirement. Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Via 0.5 VDC analog signal or potentiometer setting at controller. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
26
5.1BLV99
5.1" (130mm) BLDC Low-Voltage Blower
12/24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
27
5.1BLV99
5.7" (145mm) BLDC Low-Voltage Blower
24 VDC
Blower Data
Voltage Input Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Length Dimension "L"
Unit of Measure
VDC in. H2O mBar in. H2O, sealed mBar CFM L/sec inches mm
Part Numbers
116521* 24 1 6 15 8.2 20 39 18 2.65 67.31 116522 24 2 20 50 22 55 35 17 3.66 92.96 116450* 24 3 24 60 26 64 38 18 4.56 115.82
Air Flow
0 CFM 5 CFM 10 CFM 15 CFM 20 CFM 25 CFM 30 CFM 35 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O
Typical Performance Points Pressure
8.2 8.0 7.6 7.2 6.3 5.0 3.3 1.7 35.7 18.1 15.5 12.8 10.0 6.3 4.0 0.10 26.0 23.0 22.0 20.5 17.5 13.0 8.5 3.0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection. Input voltages listed in the chart above indicate the controller input voltage requirement. Input current: 6-10 Amps, Current is dependent on blower model. Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamp leakage max. Speed Control: Speed control is achieved at the blower controller. Refer to the controller section (PAGE 45) of this catalog for proper controller operation. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
28
5.7BLV99
5.7" (145mm) BLDC Low-Voltage Blower
24 VDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
29
5.7BLV99
5.7" (145mm) BLDC Thru Flow Blower
250 WATT, 120 VOLT
Part Number Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Inlet/Outlet Diameter Length (Dimension "I" above) Length (Dimension "L" above)
Unit of Measure
Standard Flow
116626 M 116629 E* 1 29 72 32 79 67 32 1.25 31.75 0.74 18.80 3.21 81.53 116627 M 116630 E* 2 50 124 52 129 62 29 1.25 31.75 1.65 41.91 4.12 104.65 116628 M 116631 E 3 70 174 75 186 46 22 1.25 31.75 2.5 63.50 5.02 127.51 116644 M 116647 E 1 24 60 27 67 117 55 1.75 44.45 0.76 19.30 3.28 83.31
High Flow
116645 M 116648 E 2 34 84 37 92 90 42 1.75 44.45 1.88 47.75 4.33 109.98 116646 M 116649 E 3 45 112 50 124 80 38 1.75 44.45 1.75 44.45 5.34 135.64
in. H2O mBar in. H2O mBar CFM L/sec inches mm inches mm inches mm
Typical Performance Points Air Flow
0 CFM 10 CFM 20 CFM 30 CFM 40 CFM 50 CFM 60 CFM 70 CFM 80 CFM 90 CFM 100 CFM 110 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 32.0 30.0 28.1 24.3 19.0 12.5 6.0 52.2 44.5 42.3 31.8 21.8 11.7
Pressure
75.0 52.2 34.2 21.5 8.0 27.0 26.1 25.3 23.3 23.0 21.4 18.0 16.7 13.9 10.2 6.1 2.6 37.1 34.1 31.7 28.9 25.9 21.4 17.8 12.4 5.7 .09 50.0 46.3 42.0 35.9 28.6 21.9 15.6 7.5 0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
30
5.7/250TFBHV99
5.7" (145mm) BLDC Thru Flow Blower
250 WATT, 120 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403. Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
31
5.7/250TFBHV99
5.7" (145mm) BLDC Bypass Blower
250 WATT, 120 VOLT
Part Number Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Inlet/Outlet Diameter Length (Dimension "I" above) Length (Dimension "L" above)
Unit of Measure
Standard Flow
116634 M* 116640 E* 1 29 72 32 79 68 32 1.25 31.75 0.33 8.38 5.08 129.03 116633 M 116639 E 2 48 119 56 139 63 30 1.25 31.75 1.25 31.75 6.35 161.29 116632 M* 116638 E* 3 65 161 76 188 49 23 1.25 31.75 2.14 54.36 6.89 175.01 116637 M* 116643 E* 1 26 64 27 67 115 54 1.75 44.45 0.47 11.94 5.22 132.59
High Flow
116636 M* 116642 E* 2 57.5 143 68.0 169 110 52 1.75 44.45 1.53 38.86 6.27 159.26 116635 M 116641 E 3 42 104 46 114 80 38 1.75 44.45 2.53 64.26 7.28 184.91
in. H2O mBar in. H2O mBar CFM L/sec inches mm inches mm inches mm
Typical Performance Points Air Flow
0 CFM 10 CFM 20 CFM 30 CFM 40 CFM 50 CFM 60 CFM 70 CFM 80 CFM 90 CFM 100 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 31.8 28.7 27.7 24.7 20.1 14.5 7.3 56.1 48.0 44.3 38.1 28.9 18.2 4.2
Pressure
76.2 60.3 44.1 28.9 16.1 27.1 25.0 24.4 22.9 21.2 19.1 17.2 15.0 12.2 8.0 5.5 48.1 44.0 41.6 37.9 32.2 25.8 20.5 15.8 7.1 46.0 42.8 39.2 34.9 30.0 24.3 16.2 9.8
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
32
5.7/250BHV99
5.7" (145mm) BLDC Bypass Blower
250 WATT, 120 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #640250-6 (to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
33
5.7/250BHV99
5.7" (145mm) BLDC Thru Flow Blower
400 WATT, 240 VOLT
Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Length (Dimension "I" above) Length (Dimension "L" above)
Unit of Measure
in. H2O mBar in. H2O mBar CFM L/sec inches mm inches mm
Part Number Standard Flow
117629 E* 1 28 69 31 77 67 32 .69 17.53 3.21 81.53 117630 E* 2 47 117 50 124 65 31 1.60 40.64 4.12 104.65
Air Flow
0 CFM 10 CFM 20 CFM 30 CFM 40 CFM 50 CFM 60 CFM 70 CFM
Typical Performance Points Pressure
in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 31.1 26.8 23.8 20.5 15.8 10.0 4.4 50.5 45.4 40.9 33.7 25.3 16.0 6.46
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
34
5.7/400TFBHV99
5.7" (145mm) BLDC Thru Flow Blower
400 WATT, 240 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
35
5.7/400TFBHV99
5.7" (145mm) BLDC Bypass Blower
400 WATT, 240 VOLT
Part Number Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Inlet/Outlet Diameter Length (Dimension "I" above) Length (Dimension "L" above) in. H2O mBar n. H2O mBar CFM L/sec inches mm inches mm inches mm
Unit of Measure
Standard Flow
117634 M* 117640 E* 1 28 69 30 74 69 33 1.25 31.75 2.53 64.26 5.08 129.03 117633 M 117639 E 2 45 112 51 126 62 29 1.25 31.75 1.25 31.75 5.99 152.15 117632 M* 117638 E* 3 60 149 70 174 58 27 1.25 31.75 2.14 54.36 6.89 175.01 117637 M* 117643 E* 1 23 57 25 62 114 54 1.75 44.45 .47 11.94 5.22 132.59
High Flow
117636 M* 117642 E* 2 39 97 45 112 97 46 1.75 44.45 1.53 38.86 6.27 159.26 117635 M* 117641 E* 3 53 131 61 151 86 41 1.75 44.45 2.53 64.26 7.28 184.91
Typical Performance Points Air Flow
0 CFM 10 CFM 20 CFM 30 CFM 40 CFM 50 CFM 60 CFM 70 CFM 80 CFM 90 CFM 100 CFM 110 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 30.3 27.9 26.2 23.6 19.0 13.3 7.0 3.7 51.0 44.2 41.8 35.9 27.8 16.6 3.7
Pressure
69.9 59.9 52.8 44.1 32.1 18.1 24.8 23.6 22.6 21.5 19.5 17.9 16.1 13.8 12.0 8.7 6.7 0 44.6 41.0 39.8 35.8 32.0 28.0 23.9 17.9 12.1 0 61.5 55.8 51.5 46.0 40.1 34.2 28.2 19.6 8.1
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
36
5.7/400BHV99
5.7" (145mm) BLDC Bypass Blower
400 WATT, 240 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184. Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #1-480763-0 (to be supplied by customer), mates with post header assembly. *IEC 801 testing has been completed, and specific data can be provided upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
37
5.7/400BHV99
5.7" (145mm) BLDC Bypass Blower
800 WATT, 120 VOLT
Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Inlet/Outlet Diameter Length (Dimension "I" above) Length (Dimension "L" above)
Unit of Measure
Standard Flow
117418 M* 117417 E* 3 106 263 115 285 67 32 1.25 31.75 2.12 53.85 6.87 174.50
Part Number High Flow
119102 M* 119101 E* 1 41 102 44 109 161 76 1.75 44.45 .47 11.94 5.30 134.62 119104 M* 119103 E* 2 71 176 76 188 119 56 1.75 44.45 1.53 38.86 6.35 161.29
Ultra Flow
119105 E* 1 26 64 29 72 242 114 2.75/2.50 69.85/63.50 .71 18.03 5.46 138.68
in. H2O mBar in. H2O mBar CFM L/sec inches mm inches mm inches mm
Typical Performance Points Air Flow
0 CFM 20 CFM 40 CFM 60 CFM 80 CFM 100 CFM 120 CFM 140 CFM 160 CFM 180 CFM 200 CFM 220 CFM 240 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 115.8 86.6 54.9 18.3
Pressure
44.1 41.8 39.2 34.1 29.0 23.3 14.4 7.0 0 76.2 68.4 57.2 43.5 33.2 19.8 0 29.3 27.5 26.1 23.5 21.6 17.6 15.8 14.1 11.2 8.2 5.5 2.8 1.2
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 10 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
38
5.7/800BHV99
5.7" (145mm) BLDC Bypass Blower
800 WATT, 120 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under Licence No. R9571008; Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350810-1(to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
39
5.7/800BHV99
5.7" (145mm) DC Bypass Blower
1200 WATT, 240 VOLT
Blower Data
Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Inlet/Outlet Diameter Length (Dimension "I" above) Length (Dimension "L" above)
Unit of Measure
Standard Flow
117416 M* 117415 E* 3 135 335 144 357 82 39 1.25 31.75 2.12 53.85 6.87 174.50
Part Number High Flow
119152 M* 119151 E* 1 50 124 54 134 190 90 1.75 44.45 .47 11.94 5.11 128.77 119154 M* 119153 E* 2 91 226 97 241 156 74 1.75 44.45 1.53 38.86 6.35 161.29
Ultra Flow
119155 E* 1 33 82 39 97 307 145 2.75/2.50 69.85/63.50 .70 17.78 5.47 138.94
in. H2O mBar in. H O
2
mBar CFM L/sec inches mm inches mm inches mm
Typical Performance Points Air Flow
0 CFM 20 CFM 40 CFM 60 CFM 80 CFM 100 CFM 120 CFM 140 CFM 160 CFM 180 CFM 200 CFM 220 CFM 240 CFM 260 CFM 280 CFM 300 CFM in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O in. H2O 144.3 129.1 102.9 60.8 10.8
Pressure
54.0 53.9 51.1 47.0 43.2 37.0 29.4 22.3 14.2 97.0 92.5 85.8 75.9 62.3 40.5 32.1 15.0 39.2 38.0 37.5 35.3 33.5 31.4 28.0 25.4 21.5 18.5 16.1 13.1 10.0 7.4 4.3 1.0
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
40
5.7/1200BHV99
5.7" (145mm) DC Bypass Blower
1200 WATT, 240 VOLT
NOTES (continued): Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly. *IEC 801 testing has been completed, and specific data can be provided upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
41
5.7/1200BHV99
5 Amp BLDC Blower Controller
Controller Data
Max Continuous Current Input Voltage Range Controller PWM Frequency Analog Speed Input Electrical Hall Spacing Waveform Current Limit Protection Rotation NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C
Blower Contollers
48132 5A 11-52 VDC 25 kHz 0-5 VDC 600 or 1200 8-Step Trapezoidal Yes CW / CCW
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1 to 2. Current Control: Trip point is at 5 Amp maximum.
J1-1 Vin J1-2 Vin Return (Gnd) J1-3 Analog Speed In
J4-1 Motor Phase A J4-2 Motor Phase C J4-3 Hall - (Gnd) J4-4 Hall 1 J4-5 Hall 2 J4-6 Hall 3 J4-7 Hall + (+12V)
Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. J5 Set position 1-2 for 16-52 VDC Set position 2-3 for 11-16 VDC
J4-8 Motor Phase B
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
42
5BC99
10 Amp BLDC Blower Controller
Controller Data
Max Continuous Current Input Voltage Range Controller PWM Frequency Analog Speed Input Electrical Hall Spacing Waveform Current Limit Protection Rotation NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C
Blower Contollers
48133 10 A 11-52 VDC 25 kHz 0-5 VDC 600 or 1200 8-Step Trapezoidal Yes CW / CCW
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1to 2. Current Control: Trip point is at 10 Amp maximum.
J1-1 Vin J1-2 Gnd J1-3 Analog Speed In
J4-1 Phase C J4-2 Phase B J4-3 Phase A J4-4 Hall - (Gnd) J4-5 Hall + (+12V) J4-6 Hall 1 J4-7 Hall 2
Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. J5 Set position 1-2 for 16-52 VDC Set position 2-3 for 11-16 VDC
J4-8 Hall 3
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
43
5BC99
20 Amp BLDC Motor Controller
Controller Data
Max Continuous Current Input Voltage Range Controller PWM Frequency Analog Speed Input Electrical Hall Spacing Waveform Current Limit Protection Rotation NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C
Motor Contoller
48134 20 A 11-52 VDC 25 kHz 0-5 VDC 600 or 1200 8-Step Trapezoidal Yes CW / CCW
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1 to 2. Current Control: Trip point is at 20 Amp maximum.
J4-6 Brake J4-5 Hall + J4-4 Hall 3 J4-3 Hall 2 J4-2 Hall 1 Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J5 Set to position 1-2 for 16-52 VDC operation. Set to position 2-3 for 11-16 VDC operation. J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. J4-1 Gnd
J4-12 Analog/In J4-11 Freq. Out J4-10 For./Rev. J4-9 Output Enable J4-8 Vref J4-7 Ground
J1-1 Vin J1-2 Phase A J1-3 Phase B J1-4 Phase C J1-5 Ground
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification.
44
20MC99
BLDC Motor/Blower Controller Numbers
Motor/Blower Part Numbers
119272 119275 119000 119001 119002 119003 119004 119005 119006 119007 119008 119050 119051 119052 119053 119054 119055 119056 119057 119058 119375 119380 119383 119381 119382 119384 119385 119378 119379 119396 119397 116521 116522 116450 117007** 117011** 119319** 119317**
Controller Part Numbers
48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48134 48133 48133 48133 N/A N/A N/A N/A N/A N/A 48134 48134 48133 48133 48133 48132 48132 48132 48132
Mating Cable From Controller to Blower/Motor
N/A N/A 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39831 or 39817* 39851 39851 39851 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 39685 39685 39685 39685
Input Power Cable
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 39773 39773 39773 39773 39773 39773 39773 39773 39773 N/A N/A 39773 39773 39773 39773 39773 39773 39773
Cable
39831 39817 39817-1 39817-2 39851 39851-1 39851-2 39851-3 39685 39685-1 39685-2 39685-3 39685-4 39685-5 39773 39773-1 39773-2 39773-3
mm
457.212.7 457.2 12.7 609.612.7 304.812.7 152.412.7 304.83.0 457.23.0 609.63.0 145.03.0 292.13.0 241.33.0 304.812.7 457.212.7 609.612.7 368.312.7 304.812.7 457.212.7 609.612.7
inches
18.00.50 18.00.50 24.00.50 12.00+.50 6.00.50 12.00.12 18.00.12 24.00.12 5.71.12 11.50.12 9.50.12 12.00.50 18.00.50 24.00.50 14.50.50 12.00.50 18.00.50 24.00.50
* Cable 39831 transfers hall signals from the motor to the controller. Cable 39817 does the same, but also provides cabling for analog input, tach output, braking, forward/reverse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 mAmp. ** Earlier versions of the 5.0" Minijammer blower.
45
MBCP99
PLEASE COMPLETE THIS FORM AND FAX IT TO (330) 678-8227, ATTENTION: ROTRON MARKETING DEPARTMENT DATE COMPANY ADDRESS CITY NAME TITLE TELEPHONE FAX DEPT. STATE ZIP
Complete applicable side for additional information.
Blower Sizing
Purpose of product which blower is to be incorporated in
Motor Sizing
Purpose of product which motor is to be incorporated in
Describe general operation
Describe general operation
Estimated annual requirements Power Supply Air Flow Requirements Pressure Requirements Standard Operating Point: Pressure or Vacuum Surrounding Temperature: Min. Humidity Agency Requirements: ISO9001 UL TUV CSA Other
o
Estimated annual requirements VAC To To CFM In. H2O Power Supply Speed Requirements VDC To Other RPM
VDC
Maximum Continuous Performace Requirement Speed RPM Oz. In. HP
In. H2O, Flow
CFM
Torque Power
F
Max.
o
F
Dimension, Max.: Diameter Inches, Length Inches
Surrounding Temperature: Min. Humidity Expected Life Hours Production Delivery Date Production Delivery Date Expected Price Range Expected Price Range If Replacement Current Manufacturer Model
46
o
F
Max.
o
F
Expected Life Hours
If Replacement Current Manufacturer Model
Throughout our catalog, you will find terminology used for air moving selection and product sizing. Below are a few of the key terms:
Flow
* Volume Rate/Time * AMETEK charts are in SCFM, m3/min, or L/S * SCFM = Standard Cubic Feet Per Minute (American) * Air density = 0.075 lb/cubic foot * M3/min = Cubic Meters Per Minute (Metric) * L/sec = Liters Per Second (Metric) * 1 m3/min = 35.3 SCFM * 1 L/sec = 2.119 SCFM * See Standard Engineering Conversions for other flows on pg. 44
Specific Gravity
* Density Ratio Relative to Air * Standard Air SG = 1.0 * Methane SG = 0.55
Velocity
* * * * Distance/Time or Flow/Area FPM = Feet Per Minute (American) M/min = Meters Per Minute (Metric) See Standard Engineering Conversion Chart for other velocities on pg. 44
Pressure Drop/Back Pressure/Impedance Pressure
* Force/Area * AMETEK charts are in In. H2O (IWG), PSIG, MM of Water, IHG, or mbar * IWG = Inches of Water Gauge (American) * PSIG = Pounds Per Square Inch Gauge (American) * mm of Water = Millimeter of Water Gauge (Metric) * IHG = Inches of Mercury Gauge (American) * mbar = Millibar Gauge (Metric) * PSIA = Pounds Per Square Inch Absolute (American) * 27.7 IWG = 1 PSIG * 703.58 MM of Water = 1 PSIG * 2.036 IHG = 1 PSIG * 0.069 Bars = 69 mbar = 1 PSIG * Standard Atmosphere = 0 PSIG = 14.7 PSIA * See Basic Fan Laws Chart for correcting pressure due to speed or density changes * Friction causes air to slow down and lost energy is measured in pressure drop terms * Typical pressure drop areas include piping, elbows, accessories and system * Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points * Changing the system impedance will cause the blower's work point to change
Density
* Weight/Volume * Standard Air = 0.075 lb/cubic foot
47
AE99
Standard Engineering Conversions
MULTIPLY Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Bars Bars Bars Bars British British British British British BY 76.0 29.92 406.8348 10,333 1.013 x 105 14.70 760 0.9869 1. x 10 5 1.020 x 104 14.50 0.2520 777.5 1054 107.5 2.928 x 10-4 0.01316 0.0372 136.0 0.1934 1.969 0.6 3.531 x 10-5 6.102 x 10-2 10-6 10-3 2.832 x 104 1728 0.02832 0.03704 28.32 472.0 1.6992 .02832 28.32 0.4720 62.4 16.39 5.787 x 10-4 1.639 x 10-5 105 35.31 61,023 .5885 35.3107 30.48 12 0.3048 1/3 5.30 x 10 -4 3.785 62.43 42.44 33,000 10.70 745.7 2547 2.540 10 3 0.03342 13.60 345.3 25.40 0.4912 0.002458 0.07355 25.40 2.4884 248.8 5.204 0.03613 TO OBTAIN Cms. of Mercury Inches of Mercury Inches of Water Kgs./Sq. Meter Pascals Pounds/Sq. Inch Torrs Atmospheres Dynes/Sq. Cm. Kgs./Square Meter Pounds/Sq. Inch Kilogram-Calories Foot-Pounds Joules Kilogram-Meters Kilowatt-Hours Atmospheres Inches of Water Kgs./Square Meter Pounds/Sq. Inch Feet/Minute Meters/Minute Cubic Feet Cubic Inches Cubic Meters Liters Cubic Cms. Cubic Inches Cubic Meters Cubic Yards Liters Cubic Cms./Sec. Cubic Meters/Hour Cubic Meters/Minute Liters/Minute Liters/Second Lbs. of Water/Min. Cubic Centimeters Cubic Feet Cubic Meters Cubic Centimeters Cubic Feet Cubic Inches Cubic Feet/Minute Cubic Feet/Minute Centimeters Inches Meters Yards Pounds/Square Inch Liters Pounds/Cubic Foot British Thermal Units/Min. Foot-Pounds/Min. Kg. Calories/Min. Watts British Thermal Units Centimeters Mils Atmospheres Inches of Water Kgs./Square Meter Mms. of Mercury Pounds/Square In. Atmospheres Inches of Mercury Kgs./Square Meter Millibars Pascals Pounds/Square Ft. Pounds/Square In. MULTIPLY Kgs./Cubic Meter Kilometers Kilowatts Kilowatts Kilowatts Kilowatts Kilowatt-Hours Liters Liters Liters Liters Liters/Minute Log 10 N Log N or Ln N Meters Meters Meters Meters Meters Miles Miles Miles Millibars Mms. of Mercury Mms. of Mercury Mms. of Mercury Newton Meters Ounce - Force - Inch Ounce - Force - Inch Ounce - Force - Inch Pascals Pints (Liq.) Pints (U.S. liquid) Pints (U.S. liquid) Pounds Pounds Pounds Pounds of Carbon to CO 2 Pounds of Water Pounds of Water Pounds of Water Evaporated at 212 O F Pounds/Cubic Foot Pounds/Cubic Foot Pounds-Force-Foot Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Square Centimeters Square Centimeters Square Centimeters Square Feet Square Feet Square Inches Square Inches Square Inches Square Inches Square Inches Square Kilometers Square Kilometers Square Meters Square Meters Temp. Temp. Temp. Temp. ( O C) +273 ( OC) +17.8 ( OF) +460 ( O F) -32 BY 0.06243 3281 56.92 737.6 1.341 14.34 3415 10 3 61.02 10 -3 .2642 .0353 2.303 0.4343 100 3.2808 39.37 10 -3 10 3 5280 1.6093 1760 .4019 0.0394 1.3595-3 0.01934 .7376 0.706 7.06 x 10 -3 5.21 x 10 -3 .004 28.87 473,179 16 444,823 453.6 16 14,544 27.68 0.1198 970.3 16.02 4.882 1.3558 0.06804 27.7 2.036 703.1 6.895 x 103 51.715 1.973 x 105 1.076 x 10-3 0.1550 929.0 0.09290 1.273 x 106 6.452 6.944 x 10-3 106 645.2 10.76 x 106 1.196 x 106 10.764 1.196 1 1.8 1 5/9 0.05692 10 7 44.26 1.341 x 10-3 0.01434 3.415 1.341 x 10-3 TO OBTAIN Pounds/Cubic Foot Feet British Thermal Units/Min. Foot-Pounds/Sec. Horsepower Kg.-Calories/Min. British Thermal Units Cubic Centimeters Cubic Inches Cubic Meters Gallons Cubic Feet/Minute Log EN or Ln N Log 10 N Centimeters Feet Inches Kilometers Millimeters Feet Kilometers Yards Inches of Water Inches of Mercury Kgs./Square Cm. Pounds/Square Inch Pound-Force-Foot Newton - Centimeter Newton - Meter Pound - Force - Foot Inches of Water Cubic Inches Cubic Centimeters Ounces (U.S. fluid) Dynes Grams Ounces British Thermal Units (mean) Cubic Inches Gallons British Thermal Units Kgs./Cubic Meter Kgs./Square Meter Newton Meters Atmospheres Inches of Water Inches of Mercury Kgs./Square Meter Pascals Millimeters of Mercury at 0 O C Circular Mils Square Feet Square Inches Square Centimeters Square Meters Circular Mils Square Centimeters Square Feet Square Mils Square Millimeters Square Feet Square Yards Square Feet Square Yards Abs. Temp. (O C) Temp. ( OF) Abs. Temp. ( OF) Temp. ( OC) British Thermal Units/Min. Ergs/Second Foot-Pounds/Min. Horsepower Kg.-Calories/Min. British Thermal Units Horsepower/Hours
Thermal Thermal Thermal Thermal Thermal
Units Units Units Units Units
Centimeters of Mercury Centimeters of Mercury Centimeters of Mercury Centimeters of Mercury Centimeters/Second Centimeters/Second Cubic Centimeters Cubic Centimeters Cubic Centimeters Cubic Centimeters Cubic Feet Cubic Feet Cubic Feet Cubic Feet Cubic Feet Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Inches Cubic Inches Cubic Inches Cubic Meters Cubic Meters Cubic Meters Cubic Meters/Hour Cubic Meters/Minute Feet Feet Feet Feet Feet of Air (1 atmosphere 60 O F) Gallons Grams/Cu. Cm. Horsepower Horsepower Horsepower Horsepower Horsepower-Hours Inches Inches Inches of Mercury Inches of Mercury Inches of Mercury Inches of Mercury Inches of Mercury Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water
Watts Watts Watts Watts Watts Watts-Hours Watts-Hours
48
AE99
Density Correction Chart
49
AE99
Physical Laws for Blower Applications
In the following formulae these symbols are used: P-Pressure in pounds per square inch (PSI) or inches of mercury column (inches Hg) CFM-Volume in cubic feet per minute RPM-Speed in revolutions per minute D-Density in pounds per cubic foot (lbs./cu. ft.) H-Height of air or gas column (ft.) SG-Specific Gravity (ratio of density of gas to the density of air) "Standard Air"-Air at 68O F (absolute temperature 528O) and 29.92" Hg. (barometric pressure at sea level). The density of such air is 0.075 lbs./cu. ft. and the specific volume is 13.29 cu. ft./lb. The specific gravity is 1.0. The outlet pressure of a blower depends on the condition of the air or gas at the inlet. The inlet condition is influenced by: a-Specific gravity (the ratio of density of the gas to density of standard air) b-Altitude (location of blower) c-Temperature of inlet air
Basic Fan Laws Chart
VARIABLE VOLUME PRESSURE
Varies with SQUARE of Speed Ratio P2 = P1
HORSEPOWER
Varies with CUBE of Speed Ratio HP2 = HP1
2
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio CFM2 = CFM1 WHEN DENSITY CHANGES
(
RPM2 RPM1
)
(
RPM2 RPM1
)
(
RPM2 RPM1
)
3
Does Not Change
Varies DIRECT with Density Ratio P2 = P1
Varies DIRECT with Density Ratio HP2 = HP1
()
D2 D1
()
D2 D1
Volume
The Volume changes in direct ratio to the speed.
Example - A blower is operating at 3500 RPM and delivering 1000 CFM. If the speed is reduced to 3000 RPM, what is the new volume? V1 = Original Volume (1000 CFM) V2 = New Volume RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM) V2 = V1 3000 ( RPM ) = 1000 x ( 3500 ) = 1000 x .857 = 857 CFM RPM
2 1 1 1
Pressure
Pressure (barometric) varies in direct proportion to altitude.
Example - A blower is to operate at an elevation of 6000 feet and is to deliver 3 PSI pressure. What pressure (standard air) blower is required? 29.92 Pressure = 3 x = 3.75 or 3 3/4 PSI 23.98 If it is desired to determine what pressure a 3 PSI (standard air) blower will deliver at 6000 feet - 23.98 Pressure = 3 x = 2.4 or about 2 1/2 PSI 29.92 When a blower is to operate at a high altitude it is frequently specified that the blower be capable of handling a given volume of "standard air". It is then necessary to determine the equivalent volume of air at the higher altitude. Example - A blower is to operate 6000 feet altitude and is to handle 1000 CFM of standard air. What is the CFM of air the blower must handle at 6000 feet altitude? Let: V1 = Volume of standard air (1000 CFM) V2 = Volume of thinner air Hg1 = Barometric pressure sea level (29.92) Hg2 = Barometric pressure 6000' (23.98) V2 = V1 x Hg1 = 1000 x 29.92 = 1248 CFM 23.98 Hg2
The pressure changes as the square of the speed ratio.
Example - A blower is operating at a speed of 3500 RPM and delivering air at 5.0 PSI pressure. If the speed is reduced to 3000 RPM, what is the new pressure? P1 = Original Pressure (5 PSI) P2 = New Pressure RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM) RPM2 2 3000 = 5x P2 = P 1 RPM1 3500
(
)
(
) = 5 x .735 = 3.68 PSI
AE99
2
50
The Air Density varies in inverse proportion to the absolute temperature.
Example - A blower is to handle 200O F air at 3 PSI pressure. What pressure (standard air) blower is required? Let: P1 = Pressure hot air (3 PSI) P2 = Pressure standard air AT1 = Absolute temperature hot air (200+460=660O F) AT2 = Absolute temperature standard air (68+460=528O F) P 2 = P1 x AT1 AT 2 =3x 660 528 = 3.75 or 3 3/4 PSI
Pressure varies in direct proportion to the density.
Example - A 3 PSI (standard air) blower is to be used to handle gas having a specific gravity of 0.5. What pressure does the blower create when handling the gas? Let: Pa Pg SG = Air pressure (3 PSI) = Gas pressure = Specific gravity of gas (0.5)
Pg = Pa x SG = 3 x .5 = 1.5 PSI If we are required to handle a gas having a specific gravity of 0.5 at 1.5 PSI pressure, we can determine the standard air pressure blower as follows: Let: Pa = Pg = 1.5 = 3 PSI SG .5
A blower is capable of delivering 3 PSI pressure with standard air. What pressure will it develop handling 200O F inlet air? P1 = P2 x AT2 = 3 x 528 = 2.4 or about 2 1/2 PSI 660 AT1
Horsepower
The horsepower changes as the cube of the speed ratio.
Example - A blower is operating at a speed of 3500 RPM and requiring 50 horsepower. If the speed is reduced to 3000 RPM, what is the new required horsepower? HP1 = Original Horsepower (50) HP2 = New Horsepower RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM)
HP2 = HP1 x
Horsepower vs. Specific Gravity & Ratio of Density.
The horsepower varies in direct proportion to the specific gravity (ratio of density of gas to density of air). Example - A standard air blower requires a 10 HP motor. What horsepower is required when this blower is to handle a gas whose specific gravity is 0.5? HP = 10 x 0.5 = 5 horsepower It is possible that several of the above modifications may be required on one installation. Therefore, it may be necessary to use various combinations of these formulae.
(
RPM2 RPM1
)
3
= 50 x
(
3000 3500
)
3
= 50 x .630 = 31.5 horsepower
51
AE99
AMETEK Global Operations
AMETEK Aerospace
SENSORS/MONITORING SYSTEMS * www.ametek.com/aerospace 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: 978-988-4101 * Fax: 978-988-4944
AMETEK elektromotory s.r.o.
ul. Beloveska 318 * Nachod 54701 Czech Republic Tel: 420-441-23877 * Fax: 420-441-23111
Sensors and interconnects for engines, airframes, launch vehicles and satellites, including fuel flow, temperature, speed, pressure and liquid level. Monitoring systems, including vibration. Digital bus adapters.
AVIONICS * www.ametek.com/aerospace 900 Clymer Avenue * Sellersville, PA 18960 U.S.A. Tel: 215-257-6531 * Fax: 215-257-1888
Shaded pole induction motors for heating and ventilation, thru-flow and bypass vacuum cleaner motors, and universal series drive motors.
AMETEK GmbH
Weilimdorfer Str. 47 * D-70825 Korntal-Munchingen Germany Tel: +49-711-838-7876 * Fax: +49-711-838-7862
Sales for Electromechanical Group--Europe.
Data acquisition and interface units for avionics systems. Engine indicating systems. RVSM altimeters. Fuel/hydraulic/water quality measuring systems.
GULTON-STATHAM Products * www.gultonstatham.com 1644 Whittier Avenue * Costa Mesa, CA 92627 U.S.A. Tel: 949-642-2400 * Fax: 949-642-9490
AMETEK Italia S.r.l.
CIARAMELLA * www.ametek.it Via De Barzi * Robecco Sul Naviglio 20087 Italy Tel: +39-02-946931 * Fax: +39-02-94970518
Pressure, proximity and position sensors for aircraft, engines, airborne and land-based launch vehicles, satellites, and industrial applications angle of attack sensors and stall warning computers. Mud density and smart recording transmitters for oil and gas drilling.
SERVICE OPERATIONS Distribution and Warehousing Operation * www.ametek.com/aerospace Wilmington Service Center * 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: Warehouse 978-988-4100, Service: 978-988-4729 Fax: Warehouse: 978-988-4720, Service: 978-988-4408
Universal series drive motors for outdoor power equipment, small household appliances, floor care and personal care products, and special applications.
VACUUM Products * www.ametek.it Via De Gasperi 18/A * Ripalta Cremasca 26010 Italy Tel: +39-0373-2101 * Fax: +39-0373-268200
Thru-flow and bypass vacuum motors for household, commercial, industrial canister, and upright vacuum cleaners.
Distribution of aerospace and industrial instruments, sensors, and spare parts. Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No. A8PR-221J.
Seattle Support Center * www.ametek.com/aerospace 4560 150th Avenue NE * Redmond, WA 98052 U.S.A. Tel: 425-881-1172 * Fax: 425-881-7292
AMETEK Lamb Electric
www.ameteklamb.com 627 Lake Street * Kent, OH 44240 U.S.A. Tel: 330-673-3451 * Fax: 330-673-8994
Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No. HU6R600N.
AMETEK Chemical Products
HAVEG * www.ametek.com/haveg * E-mail: haveg@ametek.com 900 Greenbank Road * Wilmington, DE 19808 U.S.A. Tel: 302-995-0400, 800-441-7777 * Fax: 302-995-0491
Motors and motor-blower systems for industrial, commercial, and household vacuum cleaners, ACUSTEK(R) motors, related floor-care equipment, and other applications such as paint sprayers, material transport, spas, and outdoor power equipment, requiring a vacuum, pressure, or drive source.
AMETEK Motors Shanghai Co. Ltd.
#1 AMETEK Road * Jiu Ting Economic Development Zone, Shanghai 201615 China Tel: 86-21-5763-2408 * Fax: 86-21-5763-2411
SILTEMP(R), ULTISIL(R), HAVEGLASTM high-thermal-resistance fabrics for welding blankets, furnace curtains, and insulation. FLEXSIL(R) molten metal filters. Corrosion-resistant HAVEG(R) tanks, towers, valves, and piping. Fluoropolymer tubing and Heat Exchangers of TEFLON*.
WESTCHESTER PLASTICS * www.ametek-westchesterplas.com Green Acres Industrial Park * Nesquehoning, PA 18240 U.S.A Tel: 570-645-2191 * Fax: 570-645-8564
Fractional horsepower electric motors and blowers for Asian and worldwide markets.
AMETEK Power and Industrial Products
www.ametek.com/power * E-mail: power.industrial@ametek.com 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: 978-988-4101 * Fax: 978-988-4179
Custom color compounding of elastomers, blends, reactive modifiers and other thermoplastic resins. Small scale pilot runs through commercial production runs. Custom color matching services.
AMETEK Dixson
DIXSON * www.ametekdixson.com 287 27 Road * Grand Junction, CO 81503 U.S.A. Tel: 888-302-0639, 970-242-8863 * Fax: 970-245-6267
Temperature, pressure, speed and flame sensors and interconnects for land, marine, and utility gas turbines and industrial boilers and burners. Gulton-Statham pressure, mud density, and smart recording transmitters for oil and gas drilling.
AMETEK Precision Instruments Europe GmbH
Rudolf-Diesel-Strasse 16 * D-40670 Meerbusch Germany Tel: +49-2159-9136-0 * Fax: +49-2159-9136-39
OEM instrumentation and data collection units for the heavy duty vehicular market. Industrial bargraph panel meters for commercial and nuclear applications. Process controls and controllers for the fast-food preparation industry.
NATIONAL CONTROLS CORP. (NCC) * www.nationalcontrols.com 1725 Western Drive * West Chicago, IL 60185 U.S.A. Tel: 630-231-5900, 800-323-2593 * Fax: 630-231-1377
Sales for Electronic Instruments Group--Europe and for AMETEK Rotron Technical Motor Division--Europe.
AMETEK Precision Instruments France SARL
3 Avenue des Coudriers, Z.A. de l'Observatoire * Montigny Le Bretonneux 78180 France Tel: 33 1 30 64 89 70 * Fax: 33 1 30 64 89 79
Time delay relays, temperature monitors and controls, solid state relays and voltage monitors, liquid level controls, and dust collectors/controls for the food industry, refrigeration, HVAC, test chambers, and other industrial applications.
PANALARM * www. panalarm.com 1725 Western Drive * West Chicago, IL 60185 U.S.A. Tel: 847-675-2500 * Fax: 847-675-3011
Sales for Electronic Instruments Group--France and for AMETEK Rotron Technical Motor Division--France.
AMETEK Precision Instruments (UK) Ltd.
www.ametek.co.uk * E-mail: sales@ametek.co.uk 2 Queens Drive, Kings Norton Business Centre * Kings Norton, Birmingham B30 3HH England Tel: 44-121-246-2260 * Fax: 44-121-246-2270
Process monitoring annunciators, control room graphic displays, and high-speed event recorders for petrochemical refineries, electrical generation and distribution, airport and train event monitoring, water and wastewater treatment plants.
AMETEK Corporate Office
www.ametek.com Station Square * Paoli, PA 19301 U.S.A. Tel: 610-647-2121, 800-473-1286 * Fax: 610-296-3412
Sales for Electronic Instruments Group--United Kingdom and Ireland. Sales for Panalarm annunciator products--Europe, Middle East, Africa, Pakistan and India. Sales for Thermox products--United Kingdom and Ireland.
52
AMETEK Process & Analytical Instruments
PROCESS INSTRUMENTS * www.ametekpi.com 455 Corporate Blvd. * Newark, DE 19702 U.S.A. Tel: 302-456-4400, 800-222-6789 * Fax: 302-456-4444
AMETEK Specialty Metal Products
METAL STRIP and SPECIALTY WIRE * www.ametekmetals.com 21 Toelles Road * Wallingford, CT 06492 U.S.A. Tel: 203-265-6731, 800-233-2266 * Fax: 203-265-6407
Continuous on-line photometric and trace moisture analyzers used for advanced process control, emissions monitoring, and product quality improvement. Markets include chemical manufacturing, semiconductor, and special packaging.
THERMOX Business Unit * www.thermox.com 150 Freeport Road * Pittsburgh, PA 15238 U.S.A. Tel: 412-828-9040 * Fax: 412-826-0399
Wrought powder metallurgy for engineered custom metal strip and wire including SEALVAR(R) iron-nickel cobalt, custom shaped wire, metal matrix composites including HIVOLTM silicon carbide aluminum, and fully dense components (FDC). FDC include vacuum sputtering targets for thin film deposits through the ISOFORMTM technology using the Pneumatic Isostatic Forging process. Product applications include satellites, land-and sea-based radar systems, computers, chip mounting, heat sinks, and reflective coatings.
THERMOX(R) oxygen analyzers for flue gas and industrial gas applications, combustion analyzers for measuring oxygen and combustibles in a single analyzer, CO monitors, and premix gas analyzers.
WESTERN RESEARCH * www.ametekpi.com 8 Manning Close N.E. * Calgary, Alberta T2E7N5 Canada Tel: 403-235-8400 * Fax: 403-248-3550
AMETEK Shanghai (SPL)
Room 16B5, Harvest Bldg. * #585 Long Hua Xi Road, Shanghai 200232 China Tel: 86-21-6428-4067, 86-21-6469-8814 * Fax: 86-21-6487-5329
Representative Office of AMETEK Singapore Pte. Ltd.
Sulfur Recovery Unit process monitoring, control, and emissions analyzers to measure air demand, SO2, H2S, NOx concentrations. Dewpoint monitors, tunable diode laser spectrometers, and temperature monitors.
AMETEK Singapore Pte. Ltd.
10 Ang Mo Kio Street 65 * #05-12 TECHPOINT 569059 Singapore Tel: 65-484-2388 * Fax: 65-481-6588 * E-mail: aspl@ametek.com.sg
AMETEK Rotron
COMMERCIAL BRUSHLESS Products * www.ametektmd.com 627 Lake Street * Kent, OH 44240 U.S.A. Tel: 330-673-3452 * Fax: 330-678-8227
Sales for all AMETEK products--Pacific Rim.
AMETEK Test and Calibration Instruments
CHATILLON(R) Force Measurement Products * www.chatillon.com 8600 Somerset Drive * Largo, FL 33773 U.S.A. Tel: 727-536-7831, 800-527-9999 * Fax: 727-539-6882
Brushless DC motors, WINDJAMMER(R) and MINIJAMMER(R) motor-blowers, and low-voltage controllers for computers, business machines, medical devices, pumps and compressors, industrial equipment, and such mass-transit vehicles as transit buses, rail cars, and locomotives.
MIL-AERO Products * www.rotron.com 9 Hasbrouck Lane * Woodstock, NY 12498 U.S.A. Tel: 914-679-2401 * Fax: 914-679-7080
Force gauges, universal testing machines, and material test instruments, automated testing software, gripping fixtures and accessories.
AMETEK Denmark A/S * www.ametek.com/tci Gydevang 32-34, PO Box 30 * DK-3450 Allerod Denmark Tel: 45-4816-8000 * Fax: 45-4816-8080
AC and brushless DC fans and blowers, heat exchanger and blower systems, fault detection devices, and electronic power conversion devices for the military and aerospace markets. Repair of products manufactured by AMETEK Rotron Technical Motor Division. FAA Repair Station No. AN1R014K.
INDUSTRIAL Products and BIOFILTRATION Products * www.rotron.com 75 North Street * Saugerties, NY 12477 U.S.A. Tel: 914-246-3401 * Fax: 914-246-3802
JOFRA temperature and pressure calibrators and FRODE PEDERSEN sensors (also markets other AMETEK instrument products throughout Europe).
LLOYD INSTRUMENTSTM Material Testing Products www.lloyd-instruments.co.uk 12 Barnes Wallis Road, Segensworth East * Fareham, Hampshire PO15 5TT England Tel: 44-1489-574221 * Fax: 44-1489-885118
I d s r a P o u t : Regenerative air blowers for pressure and vacuum applications nutil rdcs up to 1800 SCFM and 10 PSIG servicing the Industrial, Environmental, Instrumentation, & Telecommunication markets. Typical applications include solution agitation & aeration, pneumatic conveying, part hold-down and pick up, part blow off, gas & fume extraction, and process gas handling. B o i t a i nP o u t : Patented modular Biofiltration systems that remove noxious iflrto rdcs odors and vapors from gaseous exhaust and air supply systems in commercial, municipal wastewater, and industrial applications.
Materials testing machines, force gauges and test stands, melt flow indexers, friction testers, melt viscometer, density column, plastic film impact testers, and heat distortion equipment (HDT/VICAT).
MANSFIELD & GREEN Products * www.ametek.com/tci 8600 Somerset Drive * Largo, FL 33773 U.S.A. Tel: 727-536-7831, 800-527-9999 * Fax: 727-539-6882
Electronic tachometers and stroboscopes, force and torque gauges, deadweight testers, pressure calibrators, diaphragm seals, and air/noise monitoring instruments.
AMETEK Sensor Technology
PATRIOT Products * www.patriotsensors.com 1080 N. Crooks Road * Clawson, MI 48017-1097 U.S.A. Tel: 248-435-0700 * Fax: 248-435-8120
AMETEK U.S. Gauge
U.S. GAUGE Products * www.ametekusg.com 900 Clymer Ave. * Sellersville, PA 18960 U.S.A. Tel: 215-257-6531 * Fax: 215-257-3058
Position sensors including rotary cam limit switches, programmable limit switches, linear position sensors and rotary encoders; programmable controller bus cards including ultra-high speed programmable limit switches and electronic encoders for linear and rotary inputs; stamping press automation including shut height monitors; specialty products including cable and hose carrier systems. Point level sensor products including conductivity sensors, conductivity relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank gauging and leak monitoring.
DREXELBROOK Products * www.drexelbrook.com 205 Kieth Valley Road * Horsham, PA 19044 U.S.A. Tel: 215 674-1234* Fax: 215 674-2731
Pressure and temperature gauges for industrial use, process industries, and OEM applications. Pressure gauges for compressed gas, welding, and medical applications. Solid front pressure gauges and diaphragm seals for chemical, petrochemical, and other process industries. Hunter Spring NEG'ATOR(R) and SPIR'ATOR(R) constant force springs and spring powered retracting reels.
PMT Products * www.ametekusg.com 820 Pennsylvania Blvd. * Feasterville, PA 19053 U.S.A. Tel: 215-355-6900, 888-625-5895 * Fax: 215-355-2937
Pressure transducers and transmitters for industrial markets, pressure gauges, switches, transmitters, displays and cylinder sales for UHP semiconductor manufacturing markets, level measurement systems, pneumatic controllers, and gas energy content (BTU) meters.
RF and ultrasonic level sensors in a broad range of packages for chemical, petrochemical, water, waste water, food, beverage and pharmaceutical monitoring; continuous and point level sensors; IS and EX applications; line powered, low voltage, 4-20mA loop powered, HART and other networked outputs. Clarifier and sludge blanket sensor systems for wastewater applications. Level sensors for aerospace applications.
AMEKAI Taiwan Co., Ltd.
2-Floor, No. 214 Alley 1 * Lane 138, Chang-An Street * Pan-Chiao, Taipei Taiwan Tel: 886-2-2954-1765 * Fax: 886-2-2951-3443
Joint venture with Taiwanese partner. General industrial use mechanical pressure gauges for Asian and worldwide markets.
AMETEK Specialty Metal Products
CLAD METALS and METAL POWDERS * www.ametekmetals.com Route 519 * Eighty Four, PA 15330 U.S.A. Tel: 724-225-8400 * Fax: 724-225-6622
AMEKAI Meters (XIAMEN) Co., Ltd.
1-2 Floors, Chuang Xin Bldg., Torch High Technology Industrial Zone Innovate City, Xiamen, Fujian 361006 China Tel: 86-592-603-0565 * Fax: 86-592-603-0570
Stainless steel and nickel clad alloys used in high-quality cookware, sterilizers and chemical processing equipment. Stainless steel, cobalt, and nickel alloy metal powders for powder metallurgy, hardfacing, metal injection molding, polymer filtration, and plastic compounding.
Joint venture with Chinese partner. General industrial use mechanical pressure gauges for Asian and worldwide markets.
53
Contact Information
ROTRON Technical Products
627 Lake Street Kent, OH 44240 Main Tel: (330) 673-3452 Fax: (330) 678-8227 www.ametektmd.com e-mail: info@ametektmd.com AMETEK GmbH Weilimorder Str. 47 70825 Korntal-Munchingen Germany Main Tel: 49-711-838-7876 Fax: 49-711-838-7862
Distributors Allied Electronics 1-800-433-5700 www.allied.avnet.com Grainger 1-800-323-0620 www.grainger.com
54
AMETEK, Inc. AMETEK is a leading global manufacturer of electrical and electromechanical products for niche markets. Listed on the New York Stock Exchange (AME) since 1930, AMETEK's annual sales are approaching $1 billion. Operations are in North America, Europe, and Asia, with about one-third of sales to markets outside the United States. AMETEK is serving its customers with investments in new products, global and market expansion, strategic acquisitions, and operational excellence. The Company's operating groups are Electronic Instruments and Electromechanical. Rotron The Electromechanical Group (EMG) is one of the world's largest producers of high-speed electric motor products for original equipment manufacturers (OEMs). In business since 1915, EMG is using its core competencies to enhance its worldwide presence. A business unit of AMETEK EMG, Rotron has facilities in California, New York, North Carolina, and Ohio. Rotron serves the military, aerospace, medical, transportation, office equipment, industrial, and environmental markets worldwide. Rotron supports its customers with more than 650 employees that are organized in three business segments: * Technical Products * Military & Aerospace Products * Industrial Products Technical Products Rotron's standard product lines of brushless DC motors, blowers, and controllers offer a wide range of application demands. Brushless DC motors and blowers are an ideal choice for such varied applications as medical instruments, robotics, pumps, compressors, office equipment, fans, machine tools, tape drives, or any other precise rotary motion/air delivery applications. If there is a need for a product with unique performance, mounting environment, or agency requirements, Rotron can supply the solution.
ROTRON Technical Products
627 Lake Street, Kent, Ohio 44240 Telephone: 330-673-3452 * Fax: 330-678-8227 * www.ametektmd.com
(c)2000, by AMETEK, Inc. 5M200N (140044)


▲Up To Search▲   

 
Price & Availability of 48132-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X